#!/usr/bin/env bash
|
|
|
|
HOSTNAME="${COLLECTD_HOSTNAME:-$(hostname -f)}"
|
|
INTERVAL="${COLLECTD_INTERVAL:-60}"
|
|
|
|
MQTT_PORT="${COLLECTD_MQTTPORT:-1883}"
|
|
MQTT_HOST="${COLLECTD_MQTTHOST:-$(hostname -f)}"
|
|
MQTT_TOPIC="${COLLECTD_MQTTOPIC:-domoticz/in/MyMQTT}"
|
|
|
|
I2CBUS=$(/usr/sbin/i2cdetect -l | grep i2c-tiny-usb | sed -r 's/^i2c-([0-9]+).*/\1/')
|
|
|
|
S_DOOR=0
|
|
S_MOTION=1
|
|
S_SMOKE=2
|
|
S_BINARY=3
|
|
S_DIMMER=4
|
|
S_COVER=5
|
|
S_TEMP=6
|
|
S_HUM=7
|
|
S_BARO=8
|
|
S_WIND=9
|
|
S_RAIN=10
|
|
S_UV=11
|
|
S_WEIGHT=12
|
|
S_POWER=13
|
|
S_HEATER=14
|
|
S_DISTANCE=15
|
|
S_LIGHT_LEVEL=16
|
|
S_ARDUINO_NODE=17
|
|
S_ARDUINO_REPEATER_NODE=18
|
|
S_LOCK=19
|
|
S_IR=20
|
|
S_WATER=21
|
|
S_AIR_QUALITY=22
|
|
S_CUSTOM=23
|
|
S_DUST=24
|
|
S_SCENE_CONTROLLER=25
|
|
S_RGB_LIGHT=26
|
|
S_RGBW_LIGHT=27
|
|
S_COLOR_SENSOR=28
|
|
S_HVAC=29
|
|
S_MULTIMETER=30
|
|
S_SPRINKLER=31
|
|
S_WATER_LEAK=32
|
|
S_SOUND=33
|
|
S_VIBRATION=34
|
|
S_MOISTURE=35
|
|
S_INFO=36
|
|
S_GAS=37
|
|
S_GPS=38
|
|
S_WATER_QUALITY=39
|
|
|
|
V_TEMP=0
|
|
V_HUM=1
|
|
V_STATUS=2
|
|
V_PERCENTAGE=3
|
|
V_PRESSURE=4
|
|
V_FORECAST=5
|
|
V_RAIN=6
|
|
V_RAINRATE=7
|
|
V_WIND=8
|
|
V_GUST=9
|
|
V_DIRECTION=10
|
|
V_UV=11
|
|
V_WEIGHT=12
|
|
V_DISTANCE=13
|
|
V_IMPEDANCE=14
|
|
V_ARMED=15
|
|
V_TRIPPED=16
|
|
V_WATT=17
|
|
V_KWH=18
|
|
V_SCENE_ON=19
|
|
V_SCENE_OFF=20
|
|
V_HVAC_FLOW_STATE=21
|
|
V_HVAC_SPEED=22
|
|
V_LIGHT_LEVEL=23
|
|
V_UP=29
|
|
V_DOWN=30
|
|
V_STOP=31
|
|
V_IR_SEND=32
|
|
V_IR_RECEIVE=33
|
|
V_FLOW=34
|
|
V_VOLUME=35
|
|
V_LOCK_STATUS=36
|
|
V_LEVEL=37
|
|
V_VOLTAGE=38
|
|
V_CURRENT=39
|
|
V_RGB=40
|
|
V_RGBW=41
|
|
V_ID=42
|
|
V_UNIT_PREFIX=43
|
|
V_HVAC_SETPOINT_COOL=44
|
|
V_HVAC_SETPOINT_HEAT=45
|
|
V_HVAC_FLOW_MODE=46
|
|
V_TEXT=47
|
|
V_CUSTOM=48
|
|
V_POSITION=49
|
|
V_IR_RECORD=50
|
|
V_PH=51
|
|
V_ORP=52
|
|
V_EC=53
|
|
V_VAR=54
|
|
V_VA=55
|
|
V_POWER_FACTOR=56
|
|
|
|
function test_i2c_device {
|
|
if [ ! -d "/sys/bus/i2c/devices/i2c-${I2CBUS}/${I2CBUS}-00${1}" ]; then
|
|
echo "run ${2} 0x${1} > /sys/bus/i2c/devices/i2c-${I2CBUS}/new_device"
|
|
exit 2
|
|
fi
|
|
}
|
|
|
|
function humidity_to_comfort {
|
|
hum=$(echo "scale=0;$1/1" | bc)
|
|
|
|
if [[ $hum -lt 30 ]]; then
|
|
COMFORT=2
|
|
elif [[ $hum -lt 40 ]]; then
|
|
COMFORT=0
|
|
elif [[ $hum -lt 60 ]]; then
|
|
COMFORT=1
|
|
else
|
|
COMFORT=3
|
|
fi
|
|
|
|
echo $COMFORT
|
|
}
|
|
|
|
function domoticz_send {
|
|
SEND="${1}"
|
|
if nc -z ${HOSTNAME} ${DOMOTICZ_PORT}; then
|
|
curl -s -H "Accept: application/json" "$SEND" >/dev/null
|
|
else
|
|
>&2 echo "domoticz can't be reaced at ${HOSTNAME} ${DOMOTICZ_PORT}"
|
|
fi
|
|
}
|
|
|
|
function mymqtt_test {
|
|
if [ ! -x "$(which mosquitto_pub)" ]; then
|
|
>&2 echo "mosquitto_pub command is not executable or missing"
|
|
exit 2
|
|
fi
|
|
|
|
if ! nc -z ${MQTT_HOST} ${MQTT_PORT}; then
|
|
exit 0
|
|
fi
|
|
|
|
}
|
|
|
|
function mymqtt_init {
|
|
mymqtt_test
|
|
mosquitto_pub -t "${MQTT_TOPIC}/${1}/${2}/0/0/${3}" -m "${4}"
|
|
}
|
|
|
|
|
|
function mymqtt_update {
|
|
mymqtt_test
|
|
mosquitto_pub -t "${MQTT_TOPIC}/${1}/${2}/1/0/${3}" -m "${4}"
|
|
}
|
|
|
|
function mymqtt_battery {
|
|
mymqtt_test
|
|
mosquitto_pub -t "${MQTT_TOPIC}/${1}/${2}/3/0/0" -m "${3}"
|
|
}
|